Home > Api Error > Api Error Message The Server Refused Connection

Api Error Message The Server Refused Connection

Contents

Our management team welcomes your comments and suggestions on how we can improve the overall support we provide to you. This error message is typically one that you get when a firewall is preventing communication. For information, see http://kb.vmware.com/kb/1021976. Thank you.

__________________ Anton Deev Acronis Customer Central | Acronis Backup Software For more answers to your questions, try our Knowledge Base and Video Tutorials. my review here

What happens then is that the host replies to vmProtect Agent that the NFC connection has timed out, while in fact this connection is not really closed on the host side Workaround: Understand the refresh action changes both numbers until the backup operation completes. (86961) Data Protection for VMware vCenter plug-in displays in two vCenters The Data Protection for VMware vCenter plug-in also i put a licenses for the beta version. What did you accomplish with PowerShell this month? http://www-01.ibm.com/support/docview.wss?uid=swg21670711

Ans0361i Diag Vmprocessextent Error

Why is this compiled function 50x slower? Please send your comments, suggestions, or concerns to Managers or submit your feedback here.

Top Mon, 2012-09-24 16:06 #33 Luca Menghetti Offline Beginner Joined: 2012-09-22 Posts: 3 Send PM: Send PM This is a known issue regarding how the error is processed in the Data Protection for VMware vCenter plug-in when the VMCLI service stops. The restore process attempts to remove these attributes, but it is a complex process that is not always successful.

Top Wed, 2012-04-18 15:46 #5 Ron Chinte Offline Beginner Joined: 2012-04-18 Posts: 1 Send PM: Send PM IM getting this error too, and im using the latest build and update of Are there textbooks on logic where the references to set theory appear only after the construction of set theory? The LUN could be marked as offline or read only use the Windows program "diskpart". Ans9365e Vmware Vstorage Api Error For Virtual Machine To increase it, see http://kb.vmware.com/kb/1006711.

Transport: HOTADD Explanation/Actions: It is unknown if this message occurs when you use HOTADD. Error Message Proxy Server Is Refusing Connections Further investigation in the AppRecovery logs reveal the following events: WARN 2014-09-09T10:25:58 [408] - vddkApi () [NFC ERROR] NfcNetTcpRead: bRead: -1 WARN 2014-09-09T10:25:58 [408] - vddkApi () [NFC ERROR] NfcNet_Recv: requested Check our Corporate and Consumer Handbooks andOnline Documentation for help on managing your account, products and support. Workaround: Download and install the Tivoli Storage Manager Backup-Archive Client 6.4.0.1 interim fix (IC88237).

As soon as vmProtect 8 is released we will post an announcement in the forum. Veeam Vddk Error: 14009 (the Server Refused Connection) If there are no firewalls between your friend and the server, then it could also be a firewall on the server, or that the server is configured only to accept certain Divide the elements of one column with the corr element of another column I help millions of people every day, but am taken for granted by all but one What is A time to remember!

Error Message Proxy Server Is Refusing Connections

Can you tell us anything about your server and how it is configured? https://support.software.dell.com/appassure/kb/132241 DEBUG 2014-09-09T10:25:58 [408] - vddkApi () VixDiskLib: Detected DiskLib error 2338 (NBD_ERR_NETWORK_CONNECT). Ans0361i Diag Vmprocessextent Error Could you please specify it to me via PM? Ans4174e Upgrading to Tivoli Storage Manager 7.1, or newer, or using the SAN or HOTADD transport should fix this problem.

TSM function name : vmVddkFullVMOpenVMDKs TSM function : snapMoRefP is null TSM return code : 115 TSM file : vmbackvddk.cpp (7436) ANS4151E Failure mounting Virtual Machine ''. Often the error message will be reported to the console if the client is running in the command-line mode. Search All Articles About Us Company Contact Us News Partners Self Service Tools Knowledge Base Download Software Technical Documentation Training and Certification Professional Services Support Resources AppAssure Licensing Portal Boomi Support Transport: NBD, NDBSSL Explanation/Actions: It is unknown if this message occurs when you use NBD or NBDSSL. Ans9365e

Programming & Development September! Thanks to the amazing Spiceworks community, I had been researching the options... So now you know what's causing the Connection refused message you should take appropriate action e.g. get redirected here If one of the VMDK files is large or simply takes too long to be processed, the firewall can cut the idle connections of the remaining VMDKs in the sequential processing

Hello Yana, I replied to your PM message with the results. Api Return Code : 1390 Please send your comments, suggestions, or concerns to Managers or submit your feedback here.

Top Fri, 2012-09-07 14:25 #26 JP Offline Beginner Joined: 2012-06-04 Posts: 8 Send PM: Send PM I Transport: NBD, NDBSSL Explanation/Actions: A network path is not available from the data mover to the ESXi system that is hosting the target virtual machine.

Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Forums Submit Feedback Terms Of Use Knowledge Base Support User login Dear Acronis Customers,

  • We would really appreciate if you could attach these logs when posting about a technical issue.
  • Document information More support for: Tivoli Storage Manager for Virtual Environments Data Protection for VMware Software version: 6.4 Operating system(s): Linux, Windows Software edition: All Editions Reference #: 1609441 Modified date:
  • However we can still see some cases when for example the connection between the vmProtect Agent (Windows Agent) and the ESX(i) host is established via VPN and the 4Mb reads still
  • However, one or more virtual machine backups failed.
  • For example: Processing virtual machine: 10 / 11 The first number (10) is the number of virtual machines that have been processed (backed up).
  • Transport: HOTADD Explanation/Actions: An NTFS virtual disk from a Window 2012 Server might produce Error 87 when the data mover mounts the disk in read-only mode that is on an earlier
  • Message: VixDiskLib_Read => "One of the parameters supplied is invalid" Tivoli Storage Manager operations: Backup VM Transport: SAN Explanation/Actions: This error can occurs in the Fibre Channel SAN transport when there
  • I will lock this thread and if you experience any issues please create new topics for them.
  • thanks !

hi Anton, i send you new PM. I am currently running with a trail version. This is a complex problem; for a detailed explanation, see http://kb.vmware.com/kb/1018194. Ans9365e Rc 1390 Top Mon, 2012-06-11 21:05 #16 JP Offline Beginner Joined: 2012-06-04 Posts: 8 Send PM: Send PM I also need the hotfix ..

Ensure that the iSCSI target is connected to the data mover. 4) The SAN Policy must be set to OnLineAll using the Windows program called diskpart. Additional info: -------------------- Error code: 246 Module: 83 LineInfo: c61573f663f5d808 Fields: Message: Failed to execute IO operation 'Read'. -------------------- Error code: 208 Module: 83 LineInfo: c61573f663f5d77e Fields: code : 14009 Message: A link to that best practices document is supplied in each message explanation where it might be helpful to review the VMware best practices. Adeyinka, I will provide you with serial numbers for the beta version in a few minutes via a private message.

Or do we have it wrong? > > > > > > Our problem is we have been given about 30 minutes to backup an > > > application that spans This is corrected with VDDK 6.0.1 which is included in Tivoli Storage Manager Client 7.1.3.2 and higher. ESXi 5.0 How do we obtain this hotfix? This means that a new NFC connection is opened, while the old one is still used.

Divide the elements of one column with the corr element of another column Is it unethical to get paid for the work and time invested in thesis? If you have a valid support program you can upgrade for free. However, the Virtual Machine can be restored without issues. (89150) Data Protection for VMware vCenter plug-in attempts to back up invalid VMs A VM must be in the 'connected' state to At the time when the host prepares the data to be sent back the NFC connection remains idle and therefore is considered as inactive.

Luca, I sent you a private message with the details.